Спецификации
General | |
---|---|
Maximum OCV (U0) | 360 VDC |
Maximum output current (I2) | 400 Amps |
Output voltage (U2) | 50 – 200 VDC |
Duty cycle rating (X) | 100% @ 80 kw, 40° C (104° F) |
Ambient temperature/Duty cycle | Power supplies will operate between -10° C and +40° C (+14° and 104° F) |
Power factor (cosφ) | 0.98 @ 400 ADC output |
Cooling | Forced air (Class F) |
Insulation | Class H |
Mild steel cut capacity | Dross free Production pierce Maximum cutting capacity |
38 mm (1-1/2")
50 mm (2") 80 mm (3.2") |
Stainless steel cut capacity | Production pierce Maximum pierce** Severance |
45 mm (1-3/4")
75 mm (3") 80 mm (3.2") |
Aluminum cut capacity | Production pierce Severance |
45 mm (1-3/4")
80 mm (3.2") |
Speed (Mild steel) |
Book specification at highest output current |
12 mm (1/2")
4430 mm/m (170 ipm) |
Cut angle | ISO 9013 range* |
2-4
|
Weldability | Ready to weld | |
Process gases by material (Plasma/shield) |
Mild steel
Stainless steel Aluminum |
02/Air, 02/02 H35/N2, N2/N2, H35-N2/N2, F5/N2 H35/N2, Air/Air, H35-N2/N2 |
Process amps (Cutting) |
Not all processes available for all materials |
30-400 |
* ISO 9013 is a standard that defines cut quality of thermally cut parts. The lower the range (range 1 is the lowest), the smaller the angle on the cut face. Cut angle in range 4 is better than in range 5.
** Maximum pierce requires usee of an autogas console and controlled motion process. See technical documentation for details.
Отзиви